Fall arrest system failure

A harness, lanyard, lifeline or anchor that fails to stop a fall safely, through damage, poor fitting, an unrated anchor, too little clearance below, or a swing into a structure.

本页面目前仅提供英文版。

fall arrest system failure免费班前安全会讲稿

又称:Fall arrest failure, Harness failure, Lanyard failure, Anchor point failure

如何控制fall arrest system failure

  1. Prevent falls with edge protection, work platforms or a travel-restraint system, so fall arrest is the last line of defence rather than the plan.
  2. Use anchor points designed and certified for fall arrest, installed and inspected by a competent person to the manufacturer's instructions and AS/NZS 1891.
  3. Work out the fall clearance, swing-down and swing-back before rigging, and choose a lanyard or self-retracting lifeline that stops the worker before they strike the ground or a structure.
  4. Inspect harnesses, lanyards, connectors and lifelines before each use, and take out of service anything damaged or that has arrested a fall.
  5. Give each worker a harness of the right size and rating, and train them to fit, adjust and connect it correctly.
  6. Keep lines clear of sharp edges, heat and chemicals, and have a rescue plan and equipment ready to reach a suspended worker quickly.

常用的控制措施,最有效的排在前面。你的 SWMS 要针对你自己的工作和工地确定控制措施。

涵盖Fall arrest system failure的模板

按工种浏览 SWMS

常同时出现的危险

这些模板引用的法规